Operating instructions
46 
CONNECTIONS – PLUMBING 
All plumbing work must be carried out by a qualified person and in compliance with the Standard 
AS/NZS 3500.4 and all local codes and regulatory authority requirements. In New Zealand the installation 
must also conform with the New Zealand Building Code. 
All gas work must be carried out by a qualified person and in compliance with the Standard AS 5601 or 
AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority 
requirements. In New Zealand the installation must also conform with NZS 5261, as applicable under local 
regulations. 
CONNECTION SIZES 
Model 
884 024 
886 024 
Hot water connection  R¾/20         
Cold water connection  R¾/20         
Gas inlet connection  R¾/20         
Condensate drain connection  R½/15         
WATER INLET AND OUTLET 
All pipe work must be cleared of foreign matter before 
connection and purged before attempting to operate the 
water heater. All olive compression fittings must use brass 
or copper olives. Use thread sealing tape or approved 
thread sealant on all fittings. 
A full flow gate valve or ball valve must be installed on the 
cold water line or solar preheat water line to the water 
heater.  A non return valve or stop tap must not be 
installed. An acceptable arrangement is shown in the 
diagram. Refer also to “Hot Water Delivery” on page 38 
and to “Mains Water Supply” on page 37. 
A disconnection union must always be provided at the cold 
water inlet and hot water outlet on the water heater to 
allow for disconnection of the water heater. 
Insulation used on the cold and hot water lines must 
extend up to the cold water inlet and hot water outlet of the 
water heater. 
Notes: 
•  It is essential all pipe connections be correctly aligned, otherwise component connections within the 
water heater may be strained and / or components themselves misaligned. It is recommended also, 
wherever possible, pipe connections be made at the water heater first and final pipe runs be made in 
soft copper pipe to allow some adjustment for misalignment. 
•  Use the spanner flats on the water heater fittings and take care to avoid twisting the water inlet and 
outlet pipes inside the jacket. 
•  The maximum supply temperature to the water heater when used as an in-series gas booster to a solar 
water heater should not exceed 80°C. 
Gas Water Heater 
Cold (or Solar Preheat) and Hot Water 
and Gas Connection Details 