Operating instructions
INSTALLATION – WATER HEATER 
43 
DIMENSIONS AND TECHNICAL DATA 
Model 
884 024 
886 024 
Rated delivery 
(@ 40°C rise) 
litres / min 
15.0   
Recovery 
(@ 25°C rise) 
litres / min 
24   
Mass Empty 
kg 
24   
Gas Details 
Hourly Gas 
Consumption 
(MJ) 
Min Gas Pressure 
(kPa) 
Test Point Gas Pressure (kPa) 
Max Gas Pressure 
(kPa) 
minimum maximum 
Model 
024 024  024  024  024 
Natural 162 1.13 0.21 0.73 3.50 
Propane 162  2.75  0.24  1.09  3.50 
LPG 162 2.75 0.21 1.00 3.50 
Model numbers: N = Natural, P = Propane (AU), L = LPG (NZ). 
Letter N, P or L is included in the model number, e.g. 884024NF, to denote gas type. 
F = Frost protection. 
Z = New Zealand models, e.g. 884024NFZ, 884024LFZ 
Technical data is subject to change. 