Operating instructions
TEMPERATURE CONTROL – DELUXE 
25 
4.  Set the bath fill water volume 
  Press the BATH FILL VOLUME i (up button) or the 
BATH FILL VOLUME j (down button). 
The first press of either the BATH FILL VOLUME 
i (up button) or the BATH FILL VOLUME 
j (down button) will display the last selected 
bath fill water volume setting in the bath fill water 
volume display panel and the bath fill indicator light 
will glow. 
While the bath fill water volume is displayed, each 
subsequent press of the BATH FILL VOLUME 
i (up button)  or  BATH FILL  VOLUME 
j (down button) will change the water volume 
setting by 10 litres. 
When the BATH FILL VOLUME i (up button)  is 
pressed and the water volume setting is increased, 
the voice prompt will sound; 
“caution, bath fill water volume has been increased, bath may overflow” 
When the BATH FILL VOLUME j (down button) is pressed and the water volume setting is 
decreased, the voice prompt will sound; 
“bath fill water volume has been decreased” 
Pressing the BATH FILL VOLUME i (up button) or BATH FILL VOLUME j (down button) 
continuously will scroll the water volume setting. 
A maximum volume of 990 litres and a minimum volume of 10 litres can be set. The maximum 
volume of 990 litres is achieved in 10 litre increments up to 500 litres, then 990 litres is the next 
setting. 
The selected bath fill water volume will be displayed and the bath fill indicator light will glow on all 
Deluxe controllers. 
The bath fill water volume display panel will go blank 
and the bath fill indicator light will go out 3 seconds 
after the last press of either of the volume 
adjustment buttons. 
The set volume will be remembered when the 
BATH FILL button is next pressed “on”. 
5.  Close the front panel on the Deluxe controller. 
6.  Turn on the Bath Fill mode 
  Press the BATH FILL button. 
On all Deluxe controllers: 
¾  The BATH FILL operating light will glow. 
¾  The bath fill temperature setting will appear on 
the temperature display panel. 
¾  The bath fill water volume will appear on the 
bath fill water volume display panel. 
¾  The bath fill indicator light will glow. 
¾  The voice prompt will sound; 
“please set bath water volume and bath 
temperature, then open the hot water tap” 
Rheem
BATH (l)
40
°C 
120
A
CTIVE 
ON/OFFBATHFILL
B1
BATHFILL
VOLUME
BATHFILL
TEMPERATURE
ACTIVE
Lighton
2.
Adjust
Temperature
3.
Openhot
tap
4.HotWater
Press
1.
ON
/
OFF
Bath
Water
Volume
Bath
Fill
Temp
BathFi ll
SetBathFillWaterVolu me
andTemperature
1. 2.
BathFill
completed
(automatic)
BathFillButton
(Redlightflashes)
6.Closehotta p
5.
PressBath
FillButton
(Redlighton)
3.
4. Openhottap
BATHFILL
PressBath
FillB utton
(R
edlightoff)
7.
BATHFILL
“caution, 
bath fill water 
volume has been 
increased, 
bath may overflow
”
or 
“bath fill water 
volume has been 
decreased” 
Rheem
BATH (l)
40
°C 
120
A
CTIVE 
ON/OFFBATHFILL
BATHFILL
BATH (l)
40
°C 
120
A
CTIVE 
ON/OFF
Rheem
“please set 
bath water volume 
and 
 bath temperature,
 then open the 
 hot water tap” 