Operating instructions
TEMPERATURE CONTROL – DELUXE 
16 
TEMPERATURE SETTINGS – DELUXE CONTROLLERS 
The temperature settings of each type of Deluxe controller are: 
•  Bathroom1 & 2 Deluxe  37°C to 48°C* (in 1°C increments), 50°C 
•  Kitchen Deluxe  37°C to 48°C* (in 1°C increments), 50°C**, 55°C***, 60°C 
* limited to 48°C when set to Bath Fill mode on 884 and 886 series model. 
** limited to 50°C on an 886 series model. 
*** NZ – limited to 55°C. 
Temperature settings        
37  38  39  40  41  42  43  44  45  46  47  48  50  55  60 
warm    average hot shower      hot      very hot 
The installation of a Bathroom Deluxe controller(s) only (i.e. no Kitchen Deluxe controller) limits the 
temperature setting of the water heater to a maximum of: 
•  884 series  50°C 
•  886 series  50°C 
regardless of the preset outlet temperature setting of the water heater. 
The installation of a Kitchen Deluxe controller will allow a maximum temperature setting of: 
•  884 series  60°C – AU  55°C – NZ 
•  886 series  50°C 
regardless of the preset outlet temperature setting of the water heater. 
If a Deluxe controller(s) is not installed, the water heater defaults to the preset outlet temperature setting. 
This may be up to: 
•  884 series  75°C 
•  886 series  50°C 
Refer to “How Hot Should The Water Be?” on page 5. 
On a building fitted with a temperature limiting device such as a tempering valve and where an 884 series 
water heater is installed without a separate untempered hot water line to the kitchen, laundry or other non-
ablution area, although the Kitchen Deluxe controller will be able to display temperatures above 50°C and 
the water leaving the water heater will be at the set temperature, the maximum water temperature which can 
be delivered to the hot water outlets in these locations is determined by the temperature setting of the 
temperature limiting device. This is usually 50°C. 
On a building fitted with a temperature limiting device set to 50°C, enable the delivery of water temperatures 
above 50°C to the kitchen, laundry or other non-ablution area, separate untempered pipe work must be 
installed from the water heater to the hot water outlets in these locations. 