User Manual

INSTALLATION WATER HEATER
58
TECHNICAL DATA
Models
Gas type suffix
874812
876812
NF, PF
874816, 874T16
876T16
NF, NFZ, PF, LFZ
874820
876820
NF, NFZ
PF, LFZ
874826
-
LFZ
874826, 874T26
876826, 876T26
NF, NFZ, PF
Water heating capacity
@ 40°C rise
litres / min
7.5
10
12.5
15.4
16.2
Nominal capacity
@ 25°C rise
litres / min
12
16
20
24.6
26
Mass Empty (unpackaged)
kg
16
16
16
16
16
Gas Details
Hourly Gas Consumption
(MJ)
Min. Gas
Pressure
(kPa)
Max. Gas
Pressure
(kPa)
Injector Size (mm)
40 x injectors
per water heater
812
-
816
T16
820
-
826
T26
812, 816, T16,
820, 826, T26
812, 816, T16,
820, 826, T26
Natural
94
126
157
199
1.13
3.50
20 x 1.55 + 20 x 1.03
Propane
94
126
157
199
2.75
3.50
20 x 1.10 + 20 x 0.73
Universal LP Gas
-
126
157
194
2.75
3.50
20 x 1.10 + 20 x 0.73
Gas Details
Test Point Gas Pressure (kPa)
minimum
maximum
812
-
816
T16
820
-
826
T26
812
-
816
T16
820
-
826
T26
Natural
0.15
0.15
0.15
0.15
0.38
0.40
0.57
0.92
Propane
0.19
0.19
0.19
0.19
0.40
0.43
0.62
0.98
Universal LP Gas
-
0.20
0.20
0.20
-
0.41
0.61
0.94
Technical data is subject to change.
Model numbers
Gas type Letter N, P or L is included in the model number to denote gas type.
N = Natural, P = Propane (AU), L = Universal LP Gas (NZ).
E.g. 874826NF, 874826PF, 874826LFZ.
Frost protection Letter F is included in the model number to denote frost protection.
New Zealand models Letter Z is included in the model number to denote New Zealand models.
E.g. 874826NFZ, 874826LFZ.
Solar boosters /J is included in the model number to denote a Joey Grey coloured jacket.
These models are used as solar booster water heaters.
Available on 874820NF/J, 874826NF/J, 874826PF/J models only in Australia.