User Manual
TEMPERATURE CONTROL – DELUXE 
42 
Notes on the Bath Fill function: 
  The Bath Fill function can be set, turned on and turned off at any of the Deluxe controllers. 
  The Deluxe controllers do not require to have priority (PRIORITY light glowing) or be on in order to set the 
bath fill water volume or bath fill temperature or to turn the bath fill ( ) button on. 
  The bath fill ( ) button cannot be turned on whilst a hot tap is open. 
  The bath fill water volume and the bath fill temperature settings can be adjusted whilst a hot tap is open. 
  If a hot tap is not opened for six hours after the new bath fill water volume and bath fill temperature have 
been set, whilst the bath fill ( ) button is on, the settings will be automatically cancelled and will reset 
to the previous settings or to the factory default settings if no previous settings have been set. 
  The factory default bath fill water volume setting is 180 litres. 
  The factory default bath fill temperature setting is 40°C. 
  The Bath Fill function will automatically have priority when the bath fill ( ) button is pressed and the 
Bath Fill function is turned on. If the PRIORITY light is glowing on a Deluxe controller, it will go out. The 
PRIORITY light on a Deluxe controller will not glow whenever the BATH Fill operating light is on. 
  Whilst water is flowing from a hot tap during the bath fill operation (bath fill operating light is on), a Deluxe 
controller cannot be turned on or off: 
  if it is on, pressing the on / off ( ) button will not turn it off. 
  if it is off, pressing the on / off ( ) button will not turn it on. 
  Whilst there is no water flowing from a hot tap and the bath fill operating light is on, a Deluxe controller 
can be turned on (on / off ( ) button glows), but it will not gain priority (PRIORITY light will not glow). 
  Pressing the up () button or down () button above the on / off ( ) button during the bath fill operation 
(bath fill operating light is on) will not adjust the temperature setting. 
Important 
  Ensure  all  hot  taps  are  turned  off  after  a  bath  fill  operation  is  complete  and  before  pressing  the 
bath fill (  ) button “off”. Otherwise; 
  Water will flow from the hot tap when the bath fill ( ) button is pressed “off”. 
The water will be cold if all Deluxe controllers are off, or hot if a Deluxe controller has PRIORITY. 
  The voice prompt will also sound; 
“please ensure the bath hot water tap is turned off”. 