User Manual
TEMPERATURE CONTROL – DELUXE 
30 
TEMPERATURE SETTINGS – DELUXE CONTROLLERS 
The temperature settings of each type of Deluxe controller are: 
  Bathroom 1 & 2 Deluxe  37°C to 46°C (in 1°C increments), 48°C*, 50°C 
  Kitchen Deluxe  37°C to 46°C (in 1°C increments), 48°C*, 50°C**, 55°C***, 60°C 
* limited to 48°C when the Bath Fill function is set with 874 and 876 series models. 
** limited to 50°C on an 876 series model. 
*** NZ – limited to 55°C. 
Temperature settings 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
48 
50 
55 
60 
warm 
average hot shower 
hot 
very hot 
The  installation  of  a  Bathroom  Deluxe  controller(s)  only  (i.e.  no  Kitchen  Deluxe  controller)  limits  the 
temperature setting of the water heater to a maximum of: 
  874 series    50°C 
  876 series    50°C 
regardless of the preset outlet temperature setting of the water heater. 
The installation of a Kitchen Deluxe controller will allow a maximum temperature setting of: 
  874 series    60°C – AU  55°C – NZ 
  876 series    50°C 
regardless of the preset outlet temperature setting of the water heater. 
If there is no controller installed, the water heater defaults to the preset outlet temperature setting. This may 
be up to: 
  874 series    75°C 
  876 series    50°C 
Refer to “How Hot Should The Water Be?” on page 10. 
On a building fitted with a temperature limiting device such as a tempering valve and where an 874 series 
water heater is installed without a separate untempered hot water line to the kitchen, laundry or other non-
ablution area, although the Kitchen Deluxe controller will be able to display temperatures above 50°C and the 
water leaving the water heater will be at the set temperature, the maximum water temperature which can be 
delivered to the hot water outlets in these locations is determined by the temperature setting of the temperature 
limiting device. This is usually 50°C. 
On a building fitted with a temperature limiting device set to 50°C, to enable the delivery of water temperatures 
above  50°C  to  the  kitchen,  laundry  or  other  non-ablution  area,  separate  untempered  pipe  work  must  be 
installed from the water heater to the hot water outlets in these locations. 