Specifications
TM023 Integrity 26L Service Instructions REV: B
D.O.I: 17/10/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
4
Specifications
Model
871026NF
871026NF-B
875026NF
875026NF-B
871026PF
871026PF-B
875026PF
875026PF-B
Specification
Natural Propane
Max hourly gas consumption (MJ/Hr) 199 199
Min hourly gas consumption (MJ/Hr) 19 19
Min inlet water pressure (kPa) 140 140
Max inlet water pressure (kPa) 1000 1000
Min inlet gas pressure (kPa) 1.13 2.75
Max inlet gas pressure (kPa) 3.5 3.5
Max burner gas test pressure (kPa) 0.965 1.2
Min burner gas test pressure (kPa) 0.17 0.22
Ignition System Direct Spark
Power Consumption (Watts)* 146 146
Gas connection diameter (mm) R¾/20 R¾/20
Water connection diameter (mm) R¾/20 R¾/20
Relief Valve Pressure (kPa) 1750 1750
Accessories (optional)
Kitchen Controller Y Y
Bathroom 1 Controller Y Y
Bathroom 2 Controller Y Y
Deluxe Kitchen Controller Y Y
Deluxe Bathroom 1 Controller Y Y
Deluxe Bathroom 2 Controller Y Y
Recess box Y Y
Pipe cover Y Y
* Maximum power consumption when anti-frost heaters are energised.
Preset Temperature Adjustment
It is possible to choose a preset outlet water temperature setting when remote controllers
are not fitted. The water heater comes factory set at 50ºC on 871026 models or 48ºC on
875026 models.
Voltages up to 240 volts will be present within the water heater, take care
not to touch wiring terminals. Use an insulated tool when operating the
DIP switch or MIN and MAX buttons.
To adjust the preset temperature:
1. Remove the front cover from the water heater.
2. Turn DIP SWITCHES 3 and 4 on (up position) on the I.C. Board. The current preset
temperature is displayed on the LED.
3. Press the MIN or MAX button, located under the DIP Switches, until the desired
temperature is displayed. Available temperatures are:
871026: 40ºC, 43ºC, 50ºC, 55ºC and 60ºC
875026: 40ºC, 43ºC and 48ºC
4. Turn DIP SWITCHES 3 and 4 off (down position). The temperature display is now
turned off.
5. Refit the front cover to the water heater.