Specifications

TM031 Integrity 18, 20, 24, 26L Service Instructions REV: B
D.O.I: February 2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
45
Fault Finding Tests 23 28
Test 23 - Diagnostic Point 18
Test 24 - Diagnostic Point 18
Conduct test with water flowing
Conduct test with water flowing
Test Point
Connector H
Measured Value
Test Point
Connector H
Measured Value
2 White - 8 Black
DC8 16V
7 Red - 8 Black
DC8 16V
Components will be “Live” when conducting tests, exercise caution
Test 25 - Diagnostic Point 18
Test 28 - Diagnostic Point 3
Test Point
Connector H
Measured Value
Conduct test with water flowing
Measure the voltage between 11 Red and 10
Black on connector B.
Voltage should be between DC7 15V
6 Green - 8 Black
On position < DC1V
Off position DC4 6V