Specifications
Table Of Contents
- Contents
 - About Your Water Heater
- Water Heater Application
 - Model Type
 - Water Heater Operation
 - Gas Boosting For A Solar Water Heater
 - Mains Pressure
 - How Hot Should The Water Be?
 - Hotter Water Increases The Risk Of Scald Injury
 - Warning
 - Safety
 - Precautions
 - General Maintenance
 - Minor Six Month Maintenance
 - Annual Service
 - To Turn Off The Water Heater
 - To Turn On The Water Heater
 - Going On Holidays
 - Frost Protection
 - Draining The Water Heater
 - How Do I Know If The Water Heater Is Installed Correctly?
 - Victorian Customers
 - Does The Water Chemistry Affect The Water Heater?
 - How Long Will The Water Heater Last?
 
 - Water Supplies
 - Save A Service Call
- No Display On The Controller (If Fitted)
 - Cold Water From The Hot Tap
 - Water Is Too Hot Or Not Hot Enough
 - No Water From The Hot Tap
 - Water Flow Fluctuates
 - Gas Booster Operating Too Frequently
 - Fan Continues To Run After Water Heater Operation Stops
 - Smell Of Flue Gases
 - Clouds Of White ‘Vapour’ From The Flue Terminal
 - Pressure Relief Valve Discharging
 - Error Code
 - Higher Than Expected Gas Bills
 
 - Installation – Water Heater
- Installation Standards
 - Water Heater Application
 - Water Heater Location
 - Ventilation
 - Secondary Flue
 - Safe Tray
 - Pipe Cover
 - Frost Protection
 - Mains Water Supply
 - Preset Outlet Temperature Setting
 - Hot Water Delivery
 - Circulated Hot Water Flow And Return System
 - Reducing Heat Losses
 - Dimensions And Technical Data
 - Typical Installation – Indoor Location
 
 - Connections – Plumbing
 - Flueing
 - Connections – Electrical
 - Multiple Installations
 - Commissioning
 - Draining The Water Heater
 - Rheem Continuous Flow Gas Water Heater Warranty – Australia Only
 - 1. The Rheem Warranty – General
 - 2. Terms Of The Rheem Warranty And Exclusions To It
 - 3. What Is Covered By The Rheem Warranty For The Water Heaters Detailed In This Document
 - 4. Entitlement To Make A Claim Under This Warranty
 - 5. How To Make A Claim Under This Warranty
 - 6. The Australian Consumer Law
 

FLUEING 
42 
 Warning: Failure to fill with water may cause flue gasses to escape through  the condensate trap. The 
condensate trap should be regularly checked to ensure it is filled with water, replenishing when required. 
Notes 
AS/NZS 3500.4 section 5.12 is used as a guide in preparing the following drainage recommendations. 
  As the condensate is mildly acidic, copper tube and fittings must not be used as they will corrode. 
  Use UPVC (Unplasticised Polyvinyl Chloride) or PE (polyethylene) piping. 
  The outlet of the drain line must be in such a position that flow can be easily seen, but arranged so that 
discharge will not cause injury, damage or nuisance. 
  The drain line must not discharge onto electrical connections, earth stakes, copper pipe, concrete paths 
or into a pond. 