Specifications
Table Of Contents
- Contents
 - About Your Water Heater
- Water Heater Application
 - Model Type
 - Water Heater Operation
 - Gas Boosting For A Solar Water Heater
 - Mains Pressure
 - How Hot Should The Water Be?
 - Hotter Water Increases The Risk Of Scald Injury
 - Warning
 - Safety
 - Precautions
 - General Maintenance
 - Minor Six Month Maintenance
 - Annual Service
 - To Turn Off The Water Heater
 - To Turn On The Water Heater
 - Going On Holidays
 - Frost Protection
 - Draining The Water Heater
 - How Do I Know If The Water Heater Is Installed Correctly?
 - Victorian Customers
 - Does The Water Chemistry Affect The Water Heater?
 - How Long Will The Water Heater Last?
 
 - Water Supplies
 - Save A Service Call
- No Display On The Controller (If Fitted)
 - Cold Water From The Hot Tap
 - Water Is Too Hot Or Not Hot Enough
 - No Water From The Hot Tap
 - Water Flow Fluctuates
 - Gas Booster Operating Too Frequently
 - Fan Continues To Run After Water Heater Operation Stops
 - Smell Of Flue Gases
 - Clouds Of White ‘Vapour’ From The Flue Terminal
 - Pressure Relief Valve Discharging
 - Error Code
 - Higher Than Expected Gas Bills
 
 - Installation – Water Heater
- Installation Standards
 - Water Heater Application
 - Water Heater Location
 - Ventilation
 - Secondary Flue
 - Safe Tray
 - Pipe Cover
 - Frost Protection
 - Mains Water Supply
 - Preset Outlet Temperature Setting
 - Hot Water Delivery
 - Circulated Hot Water Flow And Return System
 - Reducing Heat Losses
 - Dimensions And Technical Data
 - Typical Installation – Indoor Location
 
 - Connections – Plumbing
 - Flueing
 - Connections – Electrical
 - Multiple Installations
 - Commissioning
 - Draining The Water Heater
 - Rheem Continuous Flow Gas Water Heater Warranty – Australia Only
 - 1. The Rheem Warranty – General
 - 2. Terms Of The Rheem Warranty And Exclusions To It
 - 3. What Is Covered By The Rheem Warranty For The Water Heaters Detailed In This Document
 - 4. Entitlement To Make A Claim Under This Warranty
 - 5. How To Make A Claim Under This Warranty
 - 6. The Australian Consumer Law
 

INSTALLATION – WATER HEATER 
19 
Where a temperature limiting device is installed adjacent to the in-series gas booster, the cold water line to 
the temperature limiting device can be  branched off the cold water line  either before or after the isolation 
valve and pressure limiting valve to the solar storage tank, but it MUST BE before the non return valve prior 
to an open circuit direct system. The cold water line to the temperature limiting device can be branched off 
the cold water line either before or after the non return valve prior to a closed circuit indirect system. If an 
expansion control valve is required, it must always be installed after the non return  valve and be the last 
valve prior to the solar storage tank. 
 Warning: A non return valve MUST BE installed on the cold water line to the solar storage tank AFTER 
the  cold  water branch  to  a  temperature  limiting  device  prior  to  an  open  circuit  direct  system.  Due  to  the 
higher water temperatures generated under certain conditions in the solar collectors of an open circuit direct 
solar  water  heater,  an  additional  effective  back-flow  prevention  device  also  should  be  used  as  an  extra 
safeguard. Valve manufacturer RMC recommends Dual Check Valve model N7150, as being suitable for this 
application. 
If a combination isolation valve and non return valve (duo or trio valve) is installed on the cold water line to 
an open circuit direct solar water heater and the cold water line to the temperature limiting device branches 
off after this valve, then a second non return valve must be installed between the cold water branch and the 
solar  storage  tank.  Due to  the  higher  water  temperatures  generated under  certain conditions  in  the  solar 
collectors  of  an  open  circuit  direct  pumped  solar  water  heater,  an  effective  back-flow  prevention  device 
should  be  used  as  the  second  non  return  valve  as  an  extra  safeguard.  Valve  manufacturer  RMC 
recommends Dual Check Valve model N7150, as being suitable for this application. 
If a pressure limiting valve is installed on the cold water line to the solar water heater and the cold water line 
to a  temperature limiting device  branches off before  this valve or  from another  cold water line in  the 
premises,  then  a  pressure  limiting  valve  of  an  equal  pressure  setting  may  be  required  prior  to  the 
temperature limiting device. 
In-series Gas Booster as part of an Open Circuit Direct Solar Water Heater Installation 
Two Temperature Zones Using a Temperature Limiting Device 
In-series Gas Booster as part of a Closed Circuit Solar Water Heater Installation 
Two Temperature Zones Using a Temperature Limiting Device 
LEGEND
LEGEND
from solar 
storage tank 
to solar 
storage tank 
from solar 
storage tank 
to solar 
storage tank 