Specifications
Table Of Contents
- Contents
 - About Your Water Heater
- Water Heater Application
 - Model Type
 - Water Heater Operation
 - Gas Boosting For A Solar Water Heater
 - Mains Pressure
 - How Hot Should The Water Be?
 - Hotter Water Increases The Risk Of Scald Injury
 - Warning
 - Safety
 - Precautions
 - General Maintenance
 - Minor Six Month Maintenance
 - Annual Service
 - To Turn Off The Water Heater
 - To Turn On The Water Heater
 - Going On Holidays
 - Frost Protection
 - Draining The Water Heater
 - How Do I Know If The Water Heater Is Installed Correctly?
 - Victorian Customers
 - Does The Water Chemistry Affect The Water Heater?
 - How Long Will The Water Heater Last?
 
 - Water Supplies
 - Save A Service Call
- No Display On The Controller (If Fitted)
 - Cold Water From The Hot Tap
 - Water Is Too Hot Or Not Hot Enough
 - No Water From The Hot Tap
 - Water Flow Fluctuates
 - Gas Booster Operating Too Frequently
 - Fan Continues To Run After Water Heater Operation Stops
 - Smell Of Flue Gases
 - Clouds Of White ‘Vapour’ From The Flue Terminal
 - Pressure Relief Valve Discharging
 - Error Code
 - Higher Than Expected Gas Bills
 
 - Installation – Water Heater
- Installation Standards
 - Water Heater Application
 - Water Heater Location
 - Ventilation
 - Secondary Flue
 - Safe Tray
 - Pipe Cover
 - Frost Protection
 - Mains Water Supply
 - Preset Outlet Temperature Setting
 - Hot Water Delivery
 - Circulated Hot Water Flow And Return System
 - Reducing Heat Losses
 - Dimensions And Technical Data
 - Typical Installation – Indoor Location
 
 - Connections – Plumbing
 - Flueing
 - Connections – Electrical
 - Multiple Installations
 - Commissioning
 - Draining The Water Heater
 - Rheem Continuous Flow Gas Water Heater Warranty – Australia Only
 - 1. The Rheem Warranty – General
 - 2. Terms Of The Rheem Warranty And Exclusions To It
 - 3. What Is Covered By The Rheem Warranty For The Water Heaters Detailed In This Document
 - 4. Entitlement To Make A Claim Under This Warranty
 - 5. How To Make A Claim Under This Warranty
 - 6. The Australian Consumer Law
 

SAVE A SERVICE CALL 
14 
CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL 
During the heating cycle, it is not unusual to see water vapour clouds 
steaming  from  the  flue terminal,  particularly on  cold  days. This  is 
normal operation of the water heater. 
PRESSURE RELIEF VALVE DISCHARGING 
A pressure relief valve is incorporated into the water heater controls. 
This valve protects the water heater, by allowing water to  escape, in 
the event of excessive pressure build up in the waterways. 
  Normal operation 
A  small  volume  of  water  may  discharge  from  the  bottom  of  the 
water heater when a hot tap is suddenly closed. 
  Continuous dribble 
A  continuous  dribble  may  indicate  the  water  supply  pressure  is 
above the design pressure for the water heater. If so, a pressure 
limiting  valve  must  be installed on  the  cold  water  supply pipe  to 
the water heater (refer to “Mains Water Supply” on page 17). 
ERROR CODE 
The water heater provides a diagnostic error code in the event of an interruption to its operation. The error 
code is displayed on the controller(s) (if installed) and on the OK MONITOR on the front of the water heater 
as a numerical value. If an error code appears: 
  Close the hot tap, turn off the controller(s) and switch off the 
electrical supply to the water heater. 
  Check the gas isolation valve at the gas inlet to the water heater is 
fully open. 
  Wait 5 minutes, then switch on the electrical supply to the water 
heater, turn on a controller and open a hot tap. 
If the error code persists, take note of the numerical code, turn off the 
hot  tap  and  turn  off  the  controller(s).  Phone  Rheem  Service  or  their 
nearest Accredited Service Agent to arrange for inspection. 
HIGHER THAN EXPECTED GAS BILLS 
Should you at any time, feel your gas account is too high, we suggest 
you check the following points: 
  Are outlets (especially the showers) using more hot water than you 
think? 
Very  often  it  is  not  realised  the  amount  of  hot  water  used, 
particularly when showering. Carefully review the hot water usage. 
Have your plumber fit a flow control valve to each shower outlet, 
basin and sink to reduce water usage. 
  Is the in-series gas booster operating too frequently? 
Refer to “Gas Booster Operating Too Frequently” on page 13. 
  Has there been an increase in hot water usage? 
An increase in hot water usage will result in an increase in water heater operation. 
  Has your water heating tariff rate been increased by your gas retailer since your previous account? 
IF YOU HAVE CHECKED  ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE, 
PHONE RHEEM SERVICE OR THEIR NEAREST ACCREDITED SERVICE AGENT. 