Specifications
26
SPECIFICATIONS
Note
(1)
If the supply pressure exceeds 1000kPa, a pressure limiting valve must be installed
upstream of the BWU.
(2)
Operation based on an inlet water temperature of 18ºC.
In areas with poor water quality an additional filter should be installed.
Rheem Boiling Water
Unit
70103
70203
70105
70305
70207
70307
70210
70215
70225
70240
Storage capacity (Litres)
3
5
7.5
10
15
25
40
Max supply pressure
(1)
1000kPa
Min supply pressure
50kPa
75kPa
100kPa
Cold water connection
RP½/15
Overflow / vent
connection
RP½/15
Supply voltage
220 – 250 Volts AC 50Hz
Electrical connection
10A 3 pin plug
Fixed wiring
Element
kW
1.8k
W
2.4kW
3.6kW
4.6kW
Approx Weight
Kg Empty
6
8
9
10
15
17
19
Approx Weight
Kg Full
10
15
19
22
34
47
67
Heat Up Times
Approx recovery L/hr
(2)
17.5
21
21
21
21
33
41
Approx heat time to full
capacity (mins)
(2)
12
15
22
29
40
40
50