Specifications

TM031 Integrity 24L Service Instructions REV: A
D.O.I: 30/10/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled
4
Specifications
Model
871024N0
871024NF
871024NF-B
875024NF-B
871024NF-C
875024NF-C
871024PF
871024PF-B
875024PF-B
871024PF-C
875024PF-C
Specification
Natural Propane
Max hourly gas consumption (MJ/Hr) 188 188
Min hourly gas consumption (MJ/Hr) 22 22
Min inlet water pressure (kPa) 140 140
Max inlet water pressure (kPa) 1000 1000
Min inlet gas pressure (kPa) 1.13 2.75
Max inlet gas pressure (kPa) 3.5 3.5
Ignition System Continuous Spark
Standard 64 64
Power Consumption (Watts)
With anti-frost* 146 146
Gas connection diameter (mm) R¾/20 R¾/20
Water connection diameter (mm) R¾/20 R¾/20
Relief Valve Pressure (kPa) 1750 1750
Accessories
Kitchen Controller Y Y
Bathroom 1 Controller Y Y
Bathroom 2 Controller Y Y
Deluxe Kitchen Controller Y Y
Deluxe Bathroom 1 Controller Y Y
Deluxe Bathroom 2 Controller Y Y
Recess box Y Y
Pipe cover Y Y
* Maximum power consumption when anti-frost heaters are energised.
Burner Test Point Pressures
Model
871024
871024-B
875024-B
871024-C
875024-C
Natural Gas
Max burner gas test pressure (kPa) 0.71 0.912
Min burner gas test pressure (kPa) 0.15 0.17
Propane
Max burner gas test pressure (kPa) 0.71 1.078
Min burner gas test pressure (kPa) 0.16 0.22