Specifications

TM031 Integrity 24L Service Instructions REV: A
D.O.I: 30/10/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled
25
Bath Fill Operation
Bath Fill Operation
Deluxe controllers only
B
Bath fill lamp on
Hot water volume
indicator on
Hot water volume on
Hot water temperature
indicator on
Bath fill switch on
Bath
fill switch
on less than 6
hours?
Hot water tap open
YES
Bath fill lamp off
Hot water volume
indicator off
Hot water volume off
Bath fill operation
completed
Hot water temperature
indicator off
NO
Combustion Y - Z
Bath
fill switch
off?
Water
delivered less
than or equal to set
volume?
NO
YES
Burner Off
NO
YES
Bath fill lamp flashing
Hot water volume
indicator off
Hot water volume off
Hot water temperature
indicator off
Water flow control valve
closed
Water
flow sensor
off?
65 Flashing
NO
8.5 seconds later
Hot water tap closed
YES
Bath
fill switch
off?
Bath fill lamp off
Water flow control valve
open
NO
YES