Technical data

HEAT PUMP AND TANK ASSEMBLY
33
26. Heat Pump Module Cover: Replace the front module cover and re-fit the two screws.
Step 26 Step 27
replace heat pump module remove screws
front cover from electrical cover
27. Electrical Cover: Remove the two screws securing the electrical cover, adjacent to the temperature
limiting valve cover, to the storage tank.
Remove the electrical cover from the storage tank.
Step 28 Step 29
connect wiring refit electrical front cover
to terminal block
28. Mains Power Connection: Connect the mains power supply wiring to the terminal block and earth
connection inside of the electrical cover.
Secure the conduit to the side of the storage tank with the saddle clamp and screws provided.
Refer to “Connections Electrical” on page 36.
Note: The power supply to the water heater must not be switched on until the installation is complete,
the water heater is filled with water and a satisfactory megger reading is obtained.
29. Electrical Cover: Refit the electrical cover.
30. Commissioning: Refer to Commissioning” on page 38.