Technical data

HEAT PUMP AND TANK ASSEMBLY
29
12. Flexible Braided Hoses: Retrieve the loose ends of the two flexible braided hoses from within the heat
pump module, and withdraw through the rear of the heat pump module.
13. Cold Hose Connection: Attach the flexible braided hose, marked with a blue collar, from the bottom of
the heat exchanger to the fitting in the bottom connection on the storage tank and marked “INLETin
blue.
Tighten the swivel nut on the hose using a 24 mm spanner.
Tape or sealant is not required.
Position the hose such that when the heat pump module is moved and secured to the tank, it does
not kink.
Step 13
attach flexible hose with blue collar to inlet
14. Hot Hose Connection: Attach the flexible braided hose, marked with a red collar, from the top of the
circulator to the fitting in the top connection on the storage tank and marked “OUTLET” in red.
Tighten the swivel nut on the hose using a 24 mm spanner.
Tape or sealant is not required.
Position the hose such that when the heat pump module is moved and secured to the tank, it does
not kink.
Step 14
attach flexible hose with red collar to outlet
15. Check Hoses: Check to ensure the flexible hoses are not kinked.