Technical data
COMMISSIONING 
35 
TO TURN OFF THE WATER HEATER 
If it is necessary to turn off the water heater on completion of the installation, 
such as on a building site or where the premises is vacant, then: 
  Shut down the gas control (refer to “Close Down Procedure” on page 39). 
  Close the gas isolation valve at the inlet to the gas control. 
  Close the cold water isolation valve at the inlet to the water heater. 
OUTLET TEMPERATURE COMPENSATION ADJUSTMENT – RHEEMPLUS 
The  maximum  outlet  temperature  of  a  RheemPlus  water  heater  may  be 
adjusted to compensate for temperature losses in the pipe work between the 
water heater outlet and sanitary fixtures. 
 Warning: After adjustment of the temperature limiting valve, the water 
temperature MUST NOT exceed 50°C from the first tap in the hot water pipe 
work after the water heater used for personal hygiene purposes, such as in a 
bathroom or ensuite. 
To adjust the maximum outlet temperature: 
  Ensure  the  temperature  of  the  water  in  the  water  heater  is  up  to  the 
thermostat setting on the water heater. 
The temperature of the water can be measured at the temperature pressure 
relief valve drain discharge point. Do not measure this temperature from a 
hot tap 
  Operate the easing lever on  the  temperature pressure  relief  valve  and 
place  the  thermometer  in  the  flow  of  water  from  the  relief  valve  drain 
line. 
  Remove  the  upper  plastic 
casing  and  insulation 
covering the pipe work on the 
side of the  water heater,  by 
removing  the  three (3) 
retaining  screws,  to  expose 
the temperature limiting valve. 
  Locate the first hot tap in the 
hot water  pipe  work  after the 
water  heater  used  for 
personal hygiene purposes. 
  Turn on the  hot tap  fully  to 
achieve maximum flow. 
RHEEMPLUS CASING REMOVAL