Technical data
WATER SUPPLIES 
17 
CHANGE OF WATER SUPPLY 
The changing  or  alternating from  one water  supply to another  can have  a 
detrimental effect on  the operation  and / or life expectation of  a  water heater 
cylinder and a temperature pressure relief valve. 
Where there is a changeover from one water supply to another, e.g. a rainwater 
tank  supply,  bore  water  supply,  desalinated  water  supply, public  reticulated 
water  supply  or  water  brought  in  from  another  supply,  then  water  chemistry 
information should be sought from the supplier or it should be tested to ensure 
the water  supply meets the  requirements given  in  these  guidelines for the 
Rheem warranty to apply. 
SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY 
The  water  heater  and  its  components  are  not  suitable  for  certain  water 
chemistries.  Those  chemistries  are  listed  below.  If  the  water  heater  is 
connected at any time to a water supply with the following water chemistry, the 
Rheem  warranty  will  not  cover  any  resultant  faults on  the  components  listed 
below: 
Water Chemistry 
Component 
Total Dissolved Solids (TDS) > 2500 mg/L 
water heater cylinder 
Total Dissolved Solids (TDS) 
not suitable for anode type 
water heater cylinder 
Saturation Index (SI) > +0.4 
(if expansion control valve is not fitted) 
water heater cylinder 
temperature pressure relief valve 