Specifications

TM016 Rheem Gas Permanent Pilot Service Instructions
D.O.I: 01/2006
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
6
Gas Specifications
300, 311, 314* & 811 Series
90 135 170
Indoor Outdoor Indoor Outdoor Indoor Outdoor
Min Gas Pressure (kPa) 2.75
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.18
Main Injector (mm) 1.30 1.40 1.30 1.40 1.30 1.40
Butane
Gas
Burner Pressure (kPa) 2.70
Min Gas Pressure (kPa) 1.13
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.27
Main Injector (mm) 2.25 2.45 2.45 2.60 2.45 2.80
Natural
Gas
Burner Pressure (kPa) 1.00
Min Gas Pressure (kPa) 2.75
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.18
Main Injector (mm) 1.35 1.50 1.50 1.65 1.50 1.70
Propane
Gas
Burner Pressure (kPa) 2.70
Min Gas Pressure (kPa) 0.75
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.40
Main Injector (mm) 3.80 4.00 4.20 4.50 4.20 5.60
TLP
Gas
Burner Pressure (kPa) 0.47 0.45 0.44 0.40 0.44 0.42
*314 series available in 135L & 170L outdoor models only
620 - 630 Series
130 260
Indoor Outdoor Indoor Outdoor
Min Gas Pressure (kPa) 2.75
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.18
Main Injector (mm) 1.60 1.60
Butane
Gas
Burner Pressure (kPa)
Not
Manufactured
2.70
Min Gas Pressure (kPa) 1.13
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.27
Main Injector (mm) 2.45 2.60 3.20 3.20
Natural
Gas
Burner Pressure (kPa) 1.00
Min Gas Pressure (kPa) 2.75
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.18
Main Injector (mm) 1.50 1.65 1.90 1.90
Propane
Gas
Burner Pressure (kPa) 2.70
Min Gas Pressure (kPa) 0.75
Max Gas Pressure (kPa) 3.50
Pilot Injector (mm) 0.40
Main Injector (mm) 5.80 5.80
TLP
Gas
Burner Pressure (kPa)
Not
Manufactured
0.42 0.42