Specifications
TM016 Rheem Gas Permanent Pilot Service Instructions 
D.O.I: 01/2006 
This document is stored and maintained electronically by 
 Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”. 
6
Gas Specifications 
300, 311, 314* & 811 Series 
90 135 170 
Indoor Outdoor Indoor Outdoor Indoor Outdoor
Min Gas Pressure (kPa)  2.75 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.18 
Main Injector (mm)  1.30 1.40 1.30 1.40 1.30 1.40 
Butane 
Gas 
Burner Pressure (kPa)  2.70 
Min Gas Pressure (kPa)  1.13 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.27 
Main Injector (mm)  2.25 2.45 2.45 2.60 2.45 2.80 
Natural 
Gas 
Burner Pressure (kPa)  1.00 
Min Gas Pressure (kPa)  2.75 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.18 
Main Injector (mm)  1.35 1.50 1.50 1.65 1.50 1.70 
Propane 
Gas 
Burner Pressure (kPa)  2.70 
Min Gas Pressure (kPa)  0.75 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.40 
Main Injector (mm)  3.80 4.00 4.20 4.50 4.20 5.60 
TLP 
 Gas 
Burner Pressure (kPa)  0.47 0.45 0.44 0.40 0.44 0.42 
*314 series available in 135L & 170L outdoor models only 
620 - 630 Series 
130 260 
Indoor Outdoor Indoor  Outdoor 
Min Gas Pressure (kPa)  2.75 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.18 
Main Injector (mm)  1.60  1.60 
Butane 
Gas 
Burner Pressure (kPa) 
Not 
Manufactured 
2.70 
Min Gas Pressure (kPa)  1.13 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.27 
Main Injector (mm)  2.45  2.60  3.20  3.20 
Natural 
Gas 
Burner Pressure (kPa)  1.00 
Min Gas Pressure (kPa)  2.75 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.18 
Main Injector (mm)  1.50  1.65  1.90  1.90 
Propane 
Gas 
Burner Pressure (kPa)  2.70 
Min Gas Pressure (kPa)  0.75 
Max Gas Pressure (kPa)  3.50 
Pilot Injector (mm)  0.40 
Main Injector (mm)  5.80  5.80 
TLP 
 Gas 
Burner Pressure (kPa) 
Not 
Manufactured 
0.42 0.42 