Specifications

TM016 Rheem Gas Permanent Pilot Service Instructions
D.O.I: 01/2006
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
52
Conversion Tables 620 & 630 Series – Components Required
620130 & 630130 - Natural to LP 620130 & 630130 - LP to Natural
Component Part Number Component Part Number
Gas Control LP Red (80°) 079429 Gas Control NAT Blk (80°) 079428
620130 070800 620130 070801
Burner Feed Pipe
630130 070858
Burner Feed Pipe
630130 070859
Pilot Injector 890197 Pilot Injector 890181
620130 073352 620130 073327
Burner Injector
630130 073370
Burner Injector
630130 073328
Aeration Shutter 071201 Gas Type Label 121802
Gas Type Label - Propane 121805
620260 - Natural to LP 620260 - LP to Natural
Component Part Number Component Part Number
Gas Control LP Red (60°) 079424 Gas Control NAT Blk (60°) 079421
Burner Feed Pipe 076403 Burner Feed Pipe 076401
Pilot Injector 890197 Pilot Injector 890181
Burner Injector 073323 Burner Injector 073345
Aeration Shutter 071201 Gas Type Label - Natural 121802
Gas Type Label - Propane 121805
620260 - Natural to TLP 620260 - LP to Butane
Component Part Number Component Part Number
Gas Control TWN Blue (60°) 079422 Burner Injector 073354
Burner Injector 073357 Gas Type Label - Butane 121804
Aeration Shutter 071201
Pilot Injector 890198
Gas Type Label - Towns 121801
630260 - Natural to LP 630260 - LP to Natural
Component Part Number Component Part Number
Gas Control LP Red (60°) 079424 Gas Control NAT Blk (60°) 079421
Burner Feed Pipe 076403 Burner Feed Pipe 076401
Pilot Assembly* 070955 Pilot Injector 890181
Burner Injector 073323 Burner Injector 073345
Aeration Shutter 071201 Gas Type Label - Natural 121802
Gas Type Label - Propane 121805
630260 - Natural to TLP 630260 - LP to Butane
Component Part Number Component Part Number
Gas Control TWN Blue (60°) 079422 Main Burner Injector 073354
Main Burner Injector 073357 Gas Type Label - Butane 121804
Aeration Shutter 071201
Pilot Injector 890198
Gas Type Label - Towns 121801
*When converting a 630260 outdoor heater from natural gas to LP gas the pilot assembly
is required due to the difference in size between a TS and non TS thermocouple.
Refer to the step 21 of the ‘Gas Type Conversion Procedure’ on page 50 for aeration
shutter settings.