Component Tests 5 – 7
TEST 5 TEST 6
The gap between the pilot hood and
electrode tip should be between 4 and
5mm. Gently bend the pilot hood to adjust
the spark gap.
Fit manometer to burner test point. The
burner gas pressure reading should be as
per the specifications table on page 6.
TEST 7
Fit manometer to inlet pressure test point. With ALL gas burning appliances lit,
including the water heater, the inlet gas pressure should be the minimum shown in the
gas specification table on page
6 for the particular type of gas used.
Changing the gas valve or attempting to over-gas the burner pressure will not rectify a
fault caused by insufficient line pressure.