Specifications
TM016 Rheem Gas Permanent Pilot Service Instructions
D.O.I: 01/2006
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
22
Fault Finding Chart 2
Fit the correct injector for the
model and gas type
Clean or replace the burner
feed pipe
NO
YES
YES
Replace the gas controlNO
Is
the gas supply
pressure within the
minimum and maximum
limit for the gas
type?
Tighten, clean or replace the
injector
Refer to specifications table
Fit manometer to burner
pressure test point
Is
a pressure reading
indicated?
Is
the burner
pressure reading
correct?
YES
YES
Ensure the gas control is in the pilot
position when fitting the manometer
Turn gas control knob to position “6”
TEST 7
TEST 6
Turn the gas control to the
off position and remove the
burner assembly
If possible adjust the supply
pressure or refer to installer or
gas utility. Advise customer
Is the
main burner
injector loose or
blocked?
YES
NO
YES
Is the
main burner
injector the correct
size?
NO
Is the
main burner feed
pipe blocked or
obstructed?
Is
the burner
head blocked or
damaged?
NO
Clean or replace the burner
assembly
YES
NO
Refer to specifications
table
NO
2