Specifications
COMMISSIONING
33
TO TURN OFF THE WATER HEATER
If it is necessary to turn off the water heater on completion of the installation, such as on a building site or
where the premises are vacant, then:
Switch off the electrical supply at the power outlet to the water heater (refer to note below).
Close the gas isolation valve at the inlet to the water heater.
Close the cold water isolation valve at the inlet to the water heater.
Drain the water heater if there is a risk of freezing conditions occurring (refer to “Draining The Water
Heater” on page 34).
Notes:
The frost protection system will be rendered inoperable if electrical power is not available at the water
heater.
Damage caused by freezing due to the unavailability of power at the water heater is not covered by the
Rheem warranty (refer to “Terms of the Rheem Warranty” on page 35).
If the power has been switched off to the water heater and there is a risk of freezing, then it is necessary
to drain the water heater (refer to “Draining the Water Heater” on page 34).