Specification Sheet

Rheem Manufacturing Company 3
RHPNHM2421JA
Design Variation
A = 1st Design
Voltage
J = 208/240/1/60
Cabinet Size
21 = 21" [533.4 mm] (600-1200 CFM)
Capacity
24 = 18,000/24,000 BTUH
[5.27 to 7.03 kW]
HM = A/C or HP, Multi-Position
(Upflow & Horizontal Left is the factory configuration)
Refrigerant
N = R-410A
P = 18 SEER Premium Model
Classification
H = Air Handler
Rheem
MODEL NUMBER DATA
Electrical Designation & Airflow Performance Information
2421 21 = 21.0"
1) 1/3 H.P. [249]
2) 600/800 CFM [283/378]
3) 10 x 8 [254 x 203]
4) 2 Ton
Model
Cabinet
Size
1) Motor H.P. [W]
2) Blower CFM [L/s]
1st/2nd Stage
3) Blower Wheel
Dia./Width [mm]
4) Tonnage
J = 208/240V, 1 PH, 60 Hz
Control
Designation
S = Circuit Breaker(s)
05
07
10
NOTES:
Electrical Heat Designation: See electrical heat electrical data for actual heater kW represented by number above.
Electric Heater: BTUH - (heater watts + motor watts) x 3.412 (see airflow table for motor watts).
The air handlers are shipped from the factory with the proper indoor coil installed, and cannot be ordered without a coil.
Electric heat elements are field-installed items.
The air handlers do not have an internal filter rack. An external filter rack or other means of filtration is required.
[ ] Designates Metric Conversions