Specification Sheet

Air
Electrical Data
RHPL Series
8
Model Voltage Phase HertzHP [W] RPM
Circuit
Amps.
Minimum
Circuit
Ampacity
Maximum
Circuit
Protector
HM2421 208/230 1 601/3 [249] 300-1100 1.7 4.0 15
HM3621 208/230 1 601/2 [373] 300-1100 3.4 6.0 15
HM3821 208/230 1 601/2 [373] 300-1100 3.4 6.0 15
HM4824 208/230 1 603/4 [559] 300-1100 4.9 9.0 15
HM6024 208/230 1 603/4 [559] 300-1100 4.9 9.0 15
Electrical Data – With Electric Heat
Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all
auxiliary heating requirements.
Electrical Data
• Supply circuit protective devices may be fuses or “HACR” type circuit breakers.
• Largest motor load is included in single circuit and multiple circuit 1.
• If non-standard fuse size is specified, use next size larger standard fuse size.
• J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block
without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead.
? Heater Kit Connection Type A = Breaker B = Terminal Block C = Pullout Disconnect
[ ] Designates Metric Conversions