Instructions / Assembly
    AP21850 
FIELD INSTALLATION INSTRUCTIONS 
Connected Shutoff Valve Replacement Kit - 
This kit applies only to certain models.
IMPORTANT: Read these instructions thoroughly and understand all steps and procedures before 
proceeding with the installation. Repair/Installation should only be performed by a qualified service 
technician. 
  DANGER: Make certain power to the water heater 
is “OFF” and the water in the tank is drained 
before working on the water heater for any reason. 
Failure to do so could result in property damage, 
bodily injury, or death. 
1. Turn off the water heater.   
2. Disconnect the harness coming from the water 
heater to the Shutoff Valve harness by pressing 
the locking tab. 
3.  Push the actuator pin upward to be able to 
disconnect the actuator from the brass 
valve. 
4.  Unthread the brass valve from the water 
inlet nipple. 
5.  Thread the new brass valve onto the water inlet nipple. 
6. Reconnect the new actuator to the brass valve by pushing the 
actuator pin upward.    
7. Attach the harness coming from the water heater to the new 
Shutoff Valve harness. 
8. Turn on power to the water heater. 
9. Verify no alarms are present on the display of the User Interface 
Control.  
10. Reference the Use and Care manual for any adjustments 
to temperature, mode, etc. 