Instructions / Assembly

25
Conversion instructions—LP Gas to Natural Gas
Your water heater was factory pre-set to burn natural gas but may have been converted to burn LP gas. If your water
heater has been converted to burn LP Gas, and your gas supply is now natural gas, your water heater can be converted to
burn natural gas as follows:
WARNING: This conversion kit must be installed by a
qualified installer or service technician in accordance with
these instructions. Installation must conform with local
codes, or in their absence, with the latest edition of the
National Fuel Gas Code, ANSI Z223.1/NFPA 54. Failure
to follow instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
CAUTION: The water heater is factory set to burn
natural gas, but can be converted to burn LP gas. Before
placing the water heater into operation, verify that the
type of gas supplied to your water heater and the type of
gas your water heater is set to burn are the same. If they
are not, refer to these instructions.
NOTICE: The parts required to make this conversion are
supplied in a bag attached to the water heater. Should
your heater not have this bag attached to the water
heater, a replacement can be obtained. Simply contact
the manufacturer at the address below and request a
replacement conversion kit.
Customer Service Department
1241 Carwood Court
Montgomery, AL 36117
Phone: 1-866-279-4566
Tools Required:
#20 Torx Wrench (Included)
#2 Phillips Screwdriver
3/4" Wrench
7/16" Wrench
3/8" Wrench
5/16" Wrench
Turn manual gas shut off valve to the OFF position to
shutoff gas to the thermostat.
Set the thermostat dial to the lowest setting by turning
the thermostat dial clockwise until it stops. DO
NOT FORCE.
Slightly depress the gas control knob
and turn clockwise to "OFF"
position. NOTICE: Knob cannot be
turned from "PILOT" position unless
pushed down slightly. DO NOT USE
FORCE.
Change gas regulator setting by removing cover from
the gas selector screw; then remove and reinstall the
selector screw with the blue washer and NAT arrow
mark
pointing inward toward the heater. Tighten to
4-8 in•lb. Replace cover.
Remove outer jacket door.
Remove the four screws on the inner door using the #20
TORX wrench supplied with the conversion kit.
Disconnect burner supply tube using the 3/4 in. wrench,
pilot tube using the 7/16 in. wrench, and thermocouple
using the 3/8 in. wrench from the thermostat.
Disconnect the piezo wire from piezo ignitor striker
connection. Remove the entire burner assembly along
with the
inner door.
Remove the Philips head screw that holds the pilot
burner assembly in place. Remove the pilot burner
assembly from the burner bracket. Remove the two
#6 x 3/8 in. long Philips head screws from the burner
bracket and remove the burner from inner door
assembly to expose main burner orifice.
Liquefied Petroleum (LP or Propane) to Gas Natural Gas
Gas Selector Screw
(Without cover.)
Thermostat Dial
Gas Thermostat
Piezo Wire Connection
Thermocouple (Copper
Tube)
Pilot Tube
(1/8" Aluminum Tube)
Burner Supply Tube
Piezo Igniter Striker
Front View of Gas Thermostat
Burner Door
Assembly
Outer Jacket Door
Inner Door
Gasket
Inner Door
Speed Clips
Tamper Proof
Screws
Burner Supply
Tube
Pilot Tube
Pilot Burner
Thermocouple
Supply Tube
Main Burner
Piezo Wire
LP Gas Position
Natural Gas Position
Gas Selector Screw Settings
Blue Washer Red Washer