Instructions / Assembly
23
Conversion instructions—Natural Gas to LP Gas
If your gas supply is LP gas, your water heater can be converted to burn LP gas as follows:
WARNING: This conversion kit must be installed by
a qualified installer or service technician in accordance
with these instructions. Installation must conform with
local codes, or in their absence, with the latest edition of
the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Failure to follow instructions could result in serious
injury or property damage. The qualified agency
performing this work assumes responsibility for this
conversion.
CAUTION: The water heater is factory set to burn
natural gas, but can be converted to burn LP gas.
Before placing the water heater into operation, verify
that the type of gas supplied to your water heater and
the type of gas your water heater is set to burn are the
same. If they are not, refer to these instructions.
NOTICE: The parts required to make this conversion
are supplied in a bag attached to the water heater.
Should your heater not have this bag attached to the
water heater, a replacement can be obtained. Simply
contact the manufacturer at the address below and
request a replacement conversion kit.
Customer Service Department
1241 Carwood Court
Montgomery, AL 36117
Phone: 1-866-279-4566
Tools Required:
#20 Torx Wrench (Included)
#2 Phillips Screwdriver
3/4" Wrench
7/16" Wrench
3/8" Wrench
5/16" Wrench
Turn manual gas shut off valve to the OFF position to
shutoff gas to the gas control (thermostat).
Set the gas control (thermostat) dial to the lowest
setting by turning the gas control (thermostat) dial
clockwise
until it stops. DO NOT FORCE.
Slightly depress the gas control
knob and turn clockwise
to
"OFF" position. NOTICE: Knob
cannot be turned from "PILOT"
position unless pushed down
slightly. DO NOT USE FORCE.
Change gas regulators setting by
removing cover from the gas selector screw; then
remove and reinstall the selector screw with the red
washer and LP arrow mark pointing inward toward
the heater. Tighten to 4-8 in•lb. Replace cover.
Remove outer jacket door.
Remove the four screws on the inner door using the
#20 TORX wrench supplied with the conversion kit.
Disconnect burner supply tube using the 3/4" wrench,
pilot tube using the 7/16" wrench, and thermocouple
using the 3/8" wrench from the gas control
(thermostat). Disconnect the piezo wire from piezo
ignitor striker connection. Remove the entire burner
assembly along with the inner door.
Remove the Philips head screw that holds the pilot
burner assembly in place. Remove the pilot burner
assembly from the burner bracket. Remove the two #6
x 3/8" long Philips head screws from the burner bracket
and remove the burner from inner door assembly to
expose main burner orifice.
Natural Gas to Liquefied Petroleum (LP or Propane) Gas
Burner Door
Assembly
Outer Jacket Door
Inner Door
Gasket
Inner Door
Speed Clips
Tamper Proof
Screws
Burner Supply
Tube
Pilot Tube
Main Burner
Thermocouple
Piezo Wire
Pilot Burner
LP Gas Position
Natural Gas Position
Gas Selector Screw Settings
Blue Washer
Red Washer
Gas Selector Screw
(Without cover.)
Gas Control
(thermostat) Dial
Gas control
(thermostat)
Piezo Wire Connection
Thermocouple (Copper
Tube)
Pilot Tube
(1/8" Aluminum Tube)
Burner Supply Tube
Piezo Igniter Striker
Front View of Gas Control (Thermostat)