Input / Control Panel
Mute Controls
PM2l-R
Power Control Panel
Power On / Off AC Power Connector
Powercon locking connector
Overdrive LED
Flashes red when the ampliers
protective circuitry is engaged
Signal LED
Flickers when an audio signal of at
least -30
dBu is present
Secondary Analog - AES/EBU
Input/Output
Can be congured for “priority
override”
Primary & Secondary
Ethernet Inputs
RJ-45 female;when both
are connected, change-
over to Secondary is
automatic if Primary fails.
Yellow LED ashes when
the connector is active,
glows steadily when data
is streaming. Green LEDs
glow when connected but
inactive, turn Orange to
indicate a faulty connec-
tion.
Primary Analog - AES/
EBU Input/Output &
Looping Output
XLR female; pin 1 chassis,
pin 2 +, pin 3 -
Push Button Volume Controls
Also function as a manual
Standby/On
control
Input Pad & LED Indicator
On / Off 10 dB pad for Primary Analog Input; allows input signals
of up to +24 dBu when inserted. Input Clip LED ashes red
when the Primary Analog Input preamplier is being overdriven.
AES/EBU Input Switch
When On, turns analog input 1
into an AES/EBU input
Power LED
Glows when amplier
power is On
Thermal LED
Lights to indicate that an over-
temperature sensor has shut
down the amplier
Push-To-Reset
Circuit Breakers
65