Users Manual
RSBRS02ABR
www.szrfstar.comV1.0 - Jan., 2020
3 Specifications
3.1 Absolute Maximum Ratings
Table 3. Absolute Maximum Ratings
Identification Condition Min. Typ. Max. Unit
Source & IO Battery mode 2.3 3.3 3.6 V
Operating Temperature / -40 25 +85
℃
Environmental Hot Pendulum / -20 20
℃ / Min
Notes: To ensure the RF performance, the ripple wave on the source must be less than ±300 mV.
3.2 Handling Ratings
Table 4. Handling Ratings of RSBRS02ABR
Items Condition Min. Typ. Max. Unit
Storage Temperature Tstg -40 +25 +125 ℃
Human Body Model HBM ±2000 V
Moisture Sensitivity Level 2
Charged Device Model ±250 V
3.3 RF Characteristics
3.3.1 Receiver RF Specifications
Table 5. Receiver RF Specifications
Parameters Symbol Min. Typ. Max. Unit
Sensitivity Pmin -94 dBm
Sensitivity (dirty on) Pmin -93 dBm
Maximum Input Power Pmax 0 dBm
In-band Blocking
Co-channel interference CI0 7 dB
Interferer at f
offs
= +1 MHz CI1 -1 dB
Interferer at f
offs
= -1 MHz CI1 -6 dB
Interferer at f
offs
= +2 MHz CI2 -38 dB
Interferer at f
offs
= -2 MHz CI2 -35 dB
Interferer at f
offs
= +3 MHz CI3 -42 dB
Interferer at f
offs
= -3 MHz CI3 -33 dB
Interferer at image channel (Fimage) CI4 -29 dB
Shenzhen RF-star Technology Co., Ltd. Page 12 of 22