User`s guide
SEM910
arp Manipulates the address resolution procedure table. This command is provided
primarily as a debugging tool for setting up networks.
ipaddr is the device IP
address and eaddr is the physical Ethernet address of the device
default Resets SEM configuration parameters to factory default settings. This command
does not reset the radio parameters. Use the
radio default command to reset the
radio parameters. See the section on Radio Commands for details.
echo Toggles the user screen mode to echo characters typed by the user. Default is on. If
echo is turned off, characters typed will not be displayed on the screen unless echoed
by the terminal program.
ip Sets the IP address of the SEM. The default IP address is 0.0.0.0. When specified,
netmask sets the netmask number. The default netmask is 255.255.255.0.
ping Sends inquiry packets to TCP/IP host specified in
<ipaddr> and displays the amount
of time that elapsed before a response was received. Continuously sends requests
until a key is pressed.
reset Resets the SEM and loads saved parameters into active memory. Also causes the
SEM to reinitialize which can take 30 seconds. If reset is issued before the save
command, the new parameters are lost and the last saved parameters are used.
route Displays and manipulates gateway IP addresses to route IP traffic off the subnet.
Default sets the first gateway attempted.
save Saves changed parameters in non-volatile memory to be loaded on power up. Must
be issued before the reset command or cycling power to have changed parameters
take effect. (An exception is the
sys outmax command which becomes active
immediately after it is entered.)
sys
mode displays whether SEM is configured as a Master or Slave. Setting Master or
Slave mode is performed using the bridge command. Refer to the section Bridge
Commands for details.
outmax controls how data is presented to the SEM radio. This command should not
be used without advice from Cirronet Technical Support.
version Displays the SEM firmware version.
© 2000- 2004 Cirronet™ Inc 22 M-910-0003 Rev -