If a pin is accidentally installed in the wrong connector location, simply loosen the screw,
remove the pin, re-insert it into the proper location hole and tighten the screw. Use the following
color code to insert the pins into the connector:
CONNECTOR
PIN
CONDUCTOR
COLOR
CONNECTOR
PIN
CONDUCTOR
COLOR
1 Brown 9 Green
2 Orange/Black 10 Orange
3 Black 11 Violet
4 Blue 12 Yellow
5 Tan 13 White/Black
6 Pink 14 Grey
7 White 15 White/Red
8 Red
Care must be taken to follow the color code correctly. An incorrectly assembled connector can
damage the radio or the card or both. The picture below shows the completed cable assembly.
Important Note:
If an alternate source of power is used with the SEM910DX, the minimum voltage
is +12VDC +/-10%. Failure to meet this specification can result in damage to the
remote radio assembly.