User`s guide

HN-591
Appendix A
HNWizard INIT.INI File
One of the files unpacked with the program is the INIT.INI file. It contains the entries
below and an explanation has been included on how each parameter may be used.
ErrorLevel=0
Leave this value as is. Only change it at the request of Cirronet Tech Support.
BiDirectionalHigh=55
BiDirectionalMedium=40
ReceiveHigh=55
ReceiveMedium=40
These parameters change the color levels (in percent) on the RF Tools bar
graphs/pie charts.
RFToolsInterval=1000
This parameter sets the how often bar graphs / pie charts will update (in msec)
RSSIMarginal=-60
RSSIPoor=-80
These parameters set the levels (in dBm) of color the bars on the RSSI bar chart
will display. Above the level set by RSSIMarginal, the bars will be green in
color. Between the levels set by RSSIMarginal and RSSIPoor, the bars will be
yellow in color and below the level set by RSSIPoor, the bars will be red in color.
FullShow=0, 1, 2
This changes the number of options that are viewable
0 (default) = Shows minimum amount of options.
1 = Adds all other options.
2 = Adds WinCom.
AutoDetect=1
1 = Auto-detects radio,
0 = User-defined inputs
The parameters below should not be changed as they are specific to different radios.
These parameters will come from the factory set for your radio.
-40dBm=125
-95dBm=55
When the Wizard program is opened, it reads the parameters of the HopNet radio
connected to the PC. These initial parameters are stored by the Wizard until the
program is closed. This function allows the initial parameters to be loaded into any
HopNet radio that is connected to the PC. Clicking on the Recover button displays the
settings stored when the Wizard was first opened but will not load them in the radio
until the Apply Settings is clicked. When the Apply Settings button is clicked, all the
changed values will be loaded into the radio, even if the changed values are not on the
tab currently displayed.
© 2000- 2004 Cirronet Inc 39 M-910-0012 Rev A