Specifications
Page 5–18
FOCUS System Manual
Yes APM Loop %d
ARM Failed: Address: %04d
APM Loop %d = 1 or 2, failed to arm due to neighbor address %04ds = chassis id error
No APM Loop %d Channel NOT Flipped: Time Slot %02d
Alternate Path Mode Loop %d = 1 or 2, time slots %02d = 1 - 24 did not flip
Yes APM Loop %d Flipping: Initiated by: %04d
APM Loop %d = 1 or 2, and has flipped channels to alt. path initiated by %4d = chas id
Yes APM Loop %d Going Down: Direction: %s
APM Loop %d = 1 or 2, initiating APM event due to loss of sig. in the %s = trans. (1-1,
2, 2-1, 2) direction
Yes APM Loop %d Going Inactive
Alternate Path Mode Loop %d = 1 or 2, going disabled
Information APM Loop %d ARMED
Alternate Path Mode Loop %d = 1 or 2, configured correctly and enabled
Information APM Loop %d
Armed AUTOMA
TICALLY
APM Loop %d = 1 or 2, armed when a maint. module is inserted in an armed loop
Information APM Loop %d Disarmed from %s
Alternate Path Mode Loop %d = 1 or 2, disabled by %s = chassis id
Information APM Loop %d Going Armed
Alternate Path Mode Loop %d = 1 or 2, verifying addresses before enabling
Information APM Loop %d XCVR %s
Address Change: Remote Command From Addr: %04d
APM Loop %d = 1 or 2, in trans. (1-1, 2, 2-1, 2) direction neighbor address changed by
%04d = chassis id
ALARM, EVENT TEXT,
CONCERN? EXPLANATION OF EVENT
Table 5–6. Alternate Path Mode (APM) Alarm Events.