Specifications

23.3.3 Software Settings
Once you have completed the hardware installa-
tion/connections and preliminary setup, you can
configure the FCA Module using the FOCUS
Configuration Software (FCS). See figure 23-3 for
a look at the configuration window for the FCA
module. FCA configuration includes:
•Trapping enabled or disabled
•Trap recipients
Date format
These are the only configurable items through
FCS for the FCA module. SNMP trap configura-
tion is performed with the “Configure FCA Trap
Table” (see fig. 23-4) in FCS. No Time Slot
mapping is needed for the FCA Module.
Additional configuration may be available with a
third party SNMP network manager application.
Page 23–4
FOCUS System Manual
Figure 23–1. FCA Interface Module.
Table 23–2.
FCA Module Specifications
Figure 23–2. FCA Status Indicators.
STATUS LED
INJECT/EJECT
LEVER
COMPONENT
SIDE
SOLDER
SIDE
SERIAL PORT
TX
SERIAL PORT
RX
TRAPPING
ENABLED
Catalog ID FCA
Interface One (1) RS-232C
One RJ-45 ethernet
Protocol 10/100 Base T
Indicators TX LED
RX LED
Trap Enabled
Connector DB9 female
RJ-45
Power 4.2 Watts Max.
Consumption
Operating 700mA at 6V
Current