December 2008 Page 15–3
Chapter 15. Contract Transfer (CTR) Module
15
Figure 15–3. Contact Transfer (CTR)
Module Wiring Connections.
5. Connect the proper wiring/connector to the
CTR interface module.
The CTR interface module has two 16-
position, compression-type terminal blocks,
as shown in Figure 15-2. To connect a contact
lead wire to any position on the block, turn the
screw counterclockwise, slide the wire
beneath the spring, and then tighten the screw.
You may use up to 14 AWG stranded wire.
Using Figure 15-2 and Figure 15-3 as guides,
carefully connect the wiring for your applica-
tion. Note that each circuit involves two CTR
modules: one at the “sending” end and one at
the “receiving” end. For each circuit, connect
the leads from the contact for which the status
is to be transmitted to the two positions
assigned to that circuit on the terminal block
labeled “P2” (on the CTR interface module) at
the “sending” end. Next, connect the leads
from the device that is to receive the status to
the two positions assigned to the circuit on the
terminal block labeled “P1” at the “receiving”
end. Repeat this procedure for each circuit
you are connecting to this pair of CTR
modules. The inputs and outputs are not
polarity sensitive.
15.3.2 Software Settings
There are no configurable settings for the Contact
Transfer Module, except for the DS0 channel slot
assignments.
15.4 Specifications
The Contact Transfer (CTR) Module’s technical
specifications are shown in Table 15-1.
CONTACT 1
CONTACT 2
CONTACT 3
CONTACT 4
CONTACT 5
CONTACT 6
CONTACT 7
CONTACT 8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SIG 1
SIG 2
SIG 3
SIG 4
SIG 5
SIG 6
SIG 7
SIG 8
OUT
IN
CTR
P2 P1
SIGNAL
IN
TO
INTERNAL
DEVICE
EXAMPLE:
EXAMPLE:
POS
35–300 Vdc
NEG
1
2
CONTACTTRANSFER
NEG
POS
15
16
CONTACT
OUT
Catalog ID CTR
Interfaces Eight (8) contacts, bi-directional, independent
Input Opto-isolator, 4 mA input current nominal
Output One (1) amp form “A” contact output
Indicators TX LED per circuit Channel Okay
RX LED per circuit Channel Alarm
Status LED
Connector Two (2) compression-type terminal blocks, accepting
Type up to one 14 AWG stranded wire
Back to Back 10ms
Channel Time including relay response time
Table 15–1. Contact Transfer Module (CTR) Specifications