Specifications

December 2008 Page 9–3
Chapter 9. Power Supply Module
9
LED remains red. If the other common
equipment is already installed and opera-
tional, the status LED is red at first, but turns
green within 20 seconds.
9.3.2 Software Settings
There are no software settings necessary to set up
a FOCUS Power Supply Module.
9.4 Specifications
The FOCUS Power Supply Module’s technical
specifications are shown in Table 9-1.
9.4.1 Status Indicators
This module has three status indicators, as shown
in Figure 9-2. The red/green status LED is green if
the module is functional and the rest of the
chassis/ common equipment is also functional.
The red major alarm LED, controlled by the
Maintenance Module, is lit for any of the
following conditions:
Complete power supply failure
Loss of synchronization
System alarms (e.g., nonvolatile RAM
failure/lithium battery failure, digital cross-
point switch IC failure, T1 IC framer
failure, or maintenance module failure)
•Failure of certain voltage regulator supplies
Figure 9–2.
Power Supply Module Status Indicators.
Input 24Vdc (18–30)
48/60Vdc (38–72)
110/125Vdc (88–145)
250Vdc (176–300)
120 Vac (90–130) 50/60Hz – single phase
240 Vac (176–300) 50/60Hz – single phase
Consumption Up to a maximum of 50 watts
Configuration 1 required per shelf
Optional second supply for redundancy
Diagnostics Major alarm (closes on alarm, failsafe)
Minor alarm (closes on alarm, failsafe)
Status LED
External alert (for orderwire signaling)
Connections Screw-type terminal block
Accepts up to 12 AWG wire with ring lugs
Compression, Optional for ≤14AWG wires
Table 9–1. Power Supply Module Specifications