Description Datatype Length Values Default
Software Version STRING 19 Zero-terminated String K-LD7_APP-RFB-XXXX
Base frequency UINT8 1 0 = Low, 1 = Middle, 2 = High 1 = Middle
Maximum speed UINT8 1 0 = 12.5km/h, 1 = 25km/h, 2 = 50km/h, 3 = 100km/h 1 = 25km/h
Maximum range UINT8 1 0 = 5m, 1 = 10m, 2 = 30m, 3 = 100m 1 = 10m
Threshold offset UINT8 1 10-60 dB 30 dB
Tracking filter type UINT8 1 0 = Standard, 1 = Fast detection, 2 = Long visibility 0 = Standard
Vibration suppression UINT8 1 0-16, 0 = No suppression, 16 = High suppression 2 = Low suppression
Minimum detection distance UINT8 1 0 100% of range setting 0%
Maximum detection distance UINT8 1 0 100% of range setting 50%
Minimum detection angle INT8 1 -90° to +90° -90°
Maximum detection angle INT8 1 -90° to +90° +90°
Minimum detection speed UINT8 1 0 100% of speed setting 0%
Maximum detection speed UINT8 1 0 100% of speed setting 100%
Detection direction UINT8 1 0 = Receding, 1 = Approaching, 2 = Both 2 = Both
Range threshold UINT8 1 0 100% of range setting 10%
Angle threshold INT8 1 -90° to +90°
Speed threshold UINT8 1 0 100% of speed setting 50%
Digital output 1 UINT8 1 0 = Direction, 1 = Angle, 2 = Range, 3 = Speed, 4 = Micro detection 0 = Direction
Digital output 2 UINT8 1 0 = Direction, 1 = Angle, 2 = Range, 3 = Speed, 4 = Micro detection 1 = Angle
Digital output 3 UINT8 1 0 = Direction, 1 = Angle, 2 = Range, 3 = Speed, 4 = Micro detection 2 = Range
Hold time UINT16 2 1 – 7200s (1s 2h)
120s 2min
Micro detection retrigger UINT8 1 0 = Off, 1 = Retrigger 0 = Off
Micro detection sensitivity UINT8 1 0-9, 0=Min. sensitivity, 9=Max. sensitvity 4 = Medium sensitivity
Table 12: Radar parameter structure
Parameter structure
The radar has a set of parameter which can be mo-
dified with commands. The structure can be read out
by the GRPS command and set by the SRPS com-
mand.