Param. Default Min Max Name Description
T00 00 00 01 Activate testing mode Activates the testing mode.
00: Testing mode disabled
01: Testing mode enabled
This parameter is not stored. After a reset or restart it is reset tothevalue 00.
T01 – 00 01 Force detection
output
Controls the detection output, if the testing mode T00 is enabled
00: force to low
01: force to high
T02 – 00 01 Force miscellaneous
output
Controls the miscellaneous output, if the testing mode T00 is enabled
00: force to low
01: force to high
Table 17: Class T 8-Bit testing parameters