Data Sheet

©
RFbeam Microwave GmbH | Schuppisstrasse 7 | CH-9016 St. Gallen | www.rfbeam.ch | K-LD 2 | data sheet 02 / 2020 Revision C | Page 16 / 25
Command List
All values are in hexadecimal notation unless other-
wisenoted.
Param. Default Min Max Name Description
S04 02 01 0A Sampling rate Sampling rate = value*1280Hz
Only valid after reset.
S05 10 01 40 Start up learn Number of FFT blocks that are used to learn the noise threshold average at start up.
01: no average at start up, fastest start up time
40: best average at start up, slowest start up time
Only valid after reset.
S06 01 00 03 Function of miscella-
neous output
Configurable functions of the miscellaneous output pin. The functions directly repre-
sent the detection register.
Value Function Logic Low Logic High
00 Detection No detection Valid detection
01 Direction Backward / receding Forward / approaching
02 Range Low speed range High speed range
03 Micro detection No detection Valid micro detection
Detailed information about the functions can be found in the command description of
the parameter R00.
S07 1E 14 50 Minimum
thresholdoffset
Defines the minimum threshold offset in dB with the ground line as reference.
S08 0A 01 30 Minimum
thresholdmargin
Defines the minimum margin between the noise average and the threshold curve.
S09 0A 00 FF Threshold noise
adaption speed
The speed of the noise average threshold adaption can be set with this parameter.
The value defines after how many FFT blocks the noise threshold average is adapted
again.
S0A 01 00 01 Use FFT average FFT averaging flag to reduce random noise.
00: averaging off
01: averaging on
Doubles the response and reaction time if enabled.
S0B 01 00 01 Use sensitivity
potentiometer
Flag to enable the usage of the analogue input for the sensitivity.
00: use digital sensitivity setting of parameter D01
01: use potentiometer input for sensitivity setting
S0C 01 00 01 Use hold time poten-
tiometer
Flag to enable the usage of the analogue input for the hold time.
00: use digital hold time setting of parameter D00
01: use potentiometer input for hold time setting
S0D 00 00 01 Use micro detection
for retriggering
Flag to enable the usage of the micro detection to retrigger the detection algorithm.
00: micro detection retriggering disabled
01: micro detection retriggering enabled
Table 8: Class S 8-Bit system parameters