1 OPERATING INSTRUCTIONS 1.3 Internal
Adjustments
1.2 Front Panel Indicators
PWR LED The power (PWR) LED shows that the dc supply is connected to the
amplifier.
RFO LED The RF output (RFO) LED indicates that the amplifier is being driven
and there is forward RF power present at the output.
ALARM LED The alarm (ALARM) LED illuminates if the internal temperature rises
above safe limits or high reverse power is present, output power is
automatically reduced in order to protect the amplifier.
1.3 Internal Adjustments
All internal adjustments are factory set and should not need to be changed under normal
conditions. A possible exception to this is the RF output power level which may need
to be changed to comply with local licensing requirements.
WARNING
Ensure that the power setting complies with the
requirements of your licensing authority. Failure to do
so may result in penalties being imposed by the
licensing authority.
Output Power The output power is set by RV1. This is nominally set to 100 Watts
(+50dBm), but may be set to any value between 1 and 120 Watts
depending upon local regulations in the destination country, and the
model of power amplifier.
1.4 Amplifier I/O Connections
The IP
PA500BH has four connectors on the rear panel.