User's Guide
PinPoint 721 Tag and PinPoint Tag Programmer
PinPoint 721 Tag and PinPoint Tag Programmer
To program a 721 Tag
NOTE: If you receive a “check sum” error when attempting to read or program a tag,
verify that the PTP is at least three feet away from a laptop or computer monitor.
1 Place the PTP at least three feet away from a computer
monitor or laptop.
2 Place the 721 Tag on the PTP where it says
“Place Tag Here.”
3 Open the PTP Software.
4 Select File >> Properties to verify that the correct
Comm Port is selected.
5 Click OK.
5 Do one of the following steps:
a. Enter the Tag ID of the tag you want to
program in the Tag ID field, and click Read.
b. If you do not know the Tag ID, click Read.
Once the PTP has successfully read the 721 Tag, a
dialog box appears displaying all of the Tag’s current
settings and the Tag ID appears in the Tag ID
field in the PTP software.
7 Click OK.
8 If necessary, change the settings in the PinPoint
Tag Programmer window.
9 Click Program.
10 Once the 721 Tag is successfully
reprogrammed, a message appears in the
message box indicating “Programming
Complete!”
See the table on the following page for a description of the PTP Programming options.
6
13
Cleaning and Caring for a 721 Tag
To clean a 721 Tag after use
1 Remove the 721 Tag from the asset.
2 Wet a cotton swab or paper towel with Isopropyl Alcohol.
4 Cleanse the 721 Tag.
5 Cleanse the surface of the asset.
5 Let the 721 Tag and the asset surface dry before reapplying another 721 Tag.
Use of non-approved cleaners on 721 Tags may cause permanent
damage to the Tag and will void any and all warranties.
This section provides detailed information about cleaning and caring for a 721 Tag. If
you want to use a cleaner other than, Isopropyl Alcohol, please contact RF Technologies at
(800) 669-9946,