User manual
RF Neulink
NL6000 User Guide
30
6.2. Radio Network Setup
Setting the Unit Type
1. Select
Network
ä
Unit Type
.
2. Select from the following options:
1-Base
Configure as a base station. This unit type receives
the TOID from the data packet received through the
serial port.
2-Remote
Configure as a remote. This unit type receives the
TOID from its configuration.
Setting the Unit ID (MYID)
1. Select
Network
ä
MYID
.
2. Enter a unique identification for the unit. The value must be a
hexadecimal value between 0001 and FFFE. For more information about
addressing and wildcards, refer to Section 5.4.
Setting the Target Unit ID (TOID)
You only need to set this parameter if the
Unit Type
is
Remote
. The system
ignores this parameter if the
Unit Type
is
Base
.
1. Select
Network
ä
TOID
.
2. Enter the destination address for packets from this unit. The destination
address is the MYID of the unit for which the data is intended. The value
must be a hexadecimal value in the range 0000 FFFF. For more
information about addressing and wildcards, refer to Section 5.4.
Setting the Active Channel
1. Select
Radio
ä
Select Active Channel
.
2. Enter the channel assignment for this unit. The value must be a number
in the range 01 64.
Setting the Receive Frequency
1. Select
Radio
ä
Receive Frequency for Active Channel
.
2. Enter the receive frequency for the active radio channel in MHz. The
value must be a number in the format
nnn.nnnn
.
Setting the Transmit Frequency
1. Select
Radio
ä
Transmit Frequency for Active Channel
.
2. Enter the transmit frequency for the active radio channel in MHz. The
value must be a number in the format
nnn.nnnn
.