4. Preparing for operation
4.1 Unpacking
After unpacking, inspect the device for shipping damages.
Report any damage immediately to the delivering freight forwarder
or dealer. Keep the shipping box.
4.2 Scope of delivery
1x RF2K-S Power Amplier
1x 120 V AC line cord
1x 240 V AC line cord
1x Short coaxial cable with 1x SMA connector (“Pigtail“)
1x Micro SD-Card for operating system
4.3 Selecting a location
Because of its weight the device must be situated on a stable surface.
Select a location for the device that ensures adequate air circulation
(at least 10 cm of free space in front of and behind the PA are
neccessary).
Avoid locations with extreme heat or cold, high humidity and
vibrations.
Avoid operation near TV sets, television antennas, radios and other elec
-
tromagnetic sources.
4.4 Grounding
WARNING!
NEVER connect the Ground connector (11) to a
gas or power line, as this may cause an explosion
or a electric shock!
To prevent electric shock, television interference (TVI), radio interference
(BCI) and similar problems:
Ground the device via the Ground connector (11) at its back.
For best results, use a copper wire with large cross-section to connect
to a copper rod, as long as possible, buried in conductive soil.
Keep the length of this copper wire as short as possible!
4.5 Connecting exciter
Connect the antenna socket of the exciter (a transceiver in general)
to the connector TRX (17) of the PA via a coaxial cable.
4.6 Connecting PTT-cable
Connect the PTT connector of the exciter (a transceiver in general)
to the connector PTT (7) of the PA via a RCA cable.
At the center contact (+) of the connector PTT (7) +5 V are
present.
4.7 Preparing LAN connection
Connect a ethernet cable to the LAN (13) socket.
Connect the ethernet cable to the router / switch of your local area net-
work.
4.8 Connecting antenna(s)
Do NOT transmit without an antenna or dummy load connected! Select
one or more 50 Ω antennas or dummy load with 50 Ω lead and more than
2 kW rated power.
Connect 1-4 antenna(s) to the desired 50 Ω antenna socket using
suitable coaxial cable with as little loss of power as possible, and pro-
fessionally mounted SO-239 plugs to connector ANT 1 (6), ANT 2 (5),
ANT 3 (3), ANT 4 (4).
ANT 1 (6) is looped through as long as device is “o“.
4.9 AC Line cord connection
The device works with mains voltages between 90 and 290 V AC. We re
-
commend the use of 200-240 V / 50-60 Hz AC to ensure the full performan-
ce of the device.
If the device is operated at 110 V, the maximum output power drops from
approximately 2000 W to approximately 900 W.
Connect the device with the included line cord via Power jack (9) to a
properly installed power outlet.