P a g e | 51
Only 3 pre and post delimiters total can be configured. If 3 pre-delimiters are set, no post delimiters
can be set.
Pre Data Delimiters (ABC): Select from 0 to 3 characters to display at the beginning of the card data.
These characters are shared with the post string of characters.
FAC/ID Delimiter (:): Select a character to display between and separate the FAC and ID data.
Image 66: FAC/ID
Delimiter
Post Data Delimiters (XYZ): Select from 0 to 3 characters to keystroke to the end of the card data.
These characters are shared with the pre string of characters.
Termination Keystroke (T): Adds a keystroke to the end of the card data to signify the end of the card
data.
Card Gone Delimiters (GN): Adds a keystroke to the end of the card data when the card is removed.
The Card Gone Delimiters will not be functional or enabled, only if any FIPS201 reader is connected
to the utility.