Installation Instructions

SASL User Guide v1.10 - Part # 11400-431 October 2015
8
-SOFTWARE
The BESPA is provided with a basic test program on a CD, to run on a Microsoft Windows
®
equipped Personal Computer. The program enables you to carry out a number of basic tests.
See the Technical Manual for further instruction on Software usage.
APPLICATION INTERFACE
The BESPA uses an International Standard, Application Program Interface (API) as defined in
ISO/IEC 24730-1. Further details of the API and commands are contained in the Programmer’s
Reference Guide.
-SPECIFICATIONS
ITCS-A-405
Frequency
RF Radiated Power
Regulatory Compliance
Reading/Writing
Protocols
FCC ID IC ID
Application Interface
UHF band: 860 940 MHz
1
Adjustable 0.2W to 4Watts EiRP
FCC, CFR47 Part 15.247 EN 302 208, EN 301 489-3,
EN 301 489-1, EN55022, EN55024, EN 60950-1:2005
ISO18000-6C / EPC UHF Gen 2
EM 4122 (TTO)
WFQITCS-A-405 10717A-ITCSA405
ISO/IEC 24730-1
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Dimensions
Weight
+14 to +130°F (-10 to +55°C)
-40 to +185°F (-40 to +85ºC)
5 to 85% non-condensing
24in x 24in x 4in (60 x 60 x 10 cm)
15 lbs (7 kg)
Ethernet LAN
RJ-45 Connector
Power
Current and Voltage
POE+ DC Input IEEE 802.3at Type 2
0.7Amp at +48Vdc
Antenna
Gain
2
4.6 dBi Circular Polarization
10.9 dBi Linear Polarization
1
The SASL uses the RFC RFC-6100XR RFID reader which will be factory set at time of shipping, to suit the
country of installation and use.
2
Maximum value over Operating Frequency Range as referenced to an isotropic antenna.