User Guide
SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012
10
Specifications
General
ITCS-A-200
ITCS-A-202
Frequency
UHF band: 860 – 960 MHz
1
RF Radiated Output
Power
Adjustable from 0.1 to 4 Watts EiRP
Regulatory Compliance
FCC, CFR47 Part 15.247
EN 302 208, EN 301 489-3, EN 301 489-1,
EN55022, EN55024, EN 60950-1:2005
Reading/writing
Protocols
ISO18000-6C / EPC UHF Gen 2
EM 4122 (TTO)
FCC ID
WFQITCSA200 WFQITCSA202
Application Interface
ISO/IEC 24730-1
Environmental
Operating Temperature
+14 to +130 °F (-10 to +55°C)
Storage Temperature
-40 to +85ºC
Relative Humidity
5 to 95% non-condensing
Dimensions
68 x 36 x 5”
(170 x 90 x 13 cm))
36in x 36in x 5in
(90 x 90 x 13 cm)
Weight
100 lbs (46 kg)
54 lbs (25 kg)
Ethernet LAN
Connector
RJ-45
Ethernet
10/100 BaseT
Indicators
Yellow – link operational
Green – network traffic detected
Signals
Pin 1
TXD+
Pin 5
NC
Pin 2
TXD -
Pin 6
RXD -
Pin 3
RXD+
Pin 7
NC
Pin 4
NC
Pin 8
NC
Power Supply
Input Connector
IEC/EN 60320 C14
Voltage
90 – 265 Volts AC
Frequency
47 – 63 Hz
Current
3A
Antenna
Gain
2
(circularly
polarized)
11.6 dBi
2
7.4 dBi
2
1
The SASL uses the SIRIT INfinity 610 RFID reader which will be factory set at time of shipping, to suit the
country of installation and use.
2
Nominal maximum value. Precise gain depends on transmit frequency