6. Tag Signal Strength Thresholds
Minimum At Tag To Compete: this is a measurement of the signal strength detected at the badge tag
for it to be considered to be associated with an event. Setting this to a smaller value will consider badges
that are farther away from the wall unit.
Saving Device Configuration File: The Proximity Locator Utility allows saving a set of device settings
for backup purposes. To save the currently connected Proximity Locator’s set of device settings, select the
File > Save or File > Save As menu option. This will prompt a file browser window. Select a location and a
name for this device configuration file and click the Save button. The Proximity Locator’s configuration file
is saved with a .rlc extension.
Upgrade Device Firmware: To upgrade the firmware for the A760 unit, access the Device > Upgrade
device firmware menu option. A dialog prompt will appear. Next click the Start button to begin the
upgrade process. A message indicating the firmware upgrade is complete will be displayed.
Click the Done button to finish this process. If the Proximity Locator already has the latest firmware
installed, a message will display indicating that an upgrade is not necessary.
Note: Do not disconnect the device during the upgrade process. Doing so may cause problems with the
device and its ability to upgrade the firmware properly.
Mounting
Flush Wall Mount - The A760 unit is intended to be mounted with the supplied mounting plate flush onto a
wall. However, it can also be mounted under a cabinet, for example, if use-case testing yields satisfactory
results.
1. Attach the mounting plate to the mounting surface using anchors and screws (not supplied) or
mounting adhesive (not supplied).
2. Slide the A760 unit onto the mounting plate. Ensure it is secure.
3. Snap the plastic cover onto the unit.
Environmental Limits
The A760 unit is approved for use within the ranges set forth below.
Operation: -20 to +70 degrees Celsius
Humidity: 10% to 90% RH non-condensing
Warranty & Service
Limited Standard Warranty Terms
RF Code warrants its products to be free from defects in materials and workmanship for a
period of 1 year (12 months) for hardware and software from the date of purchase from RF
Code. Its obligation under this warranty is limited to repairing or replacing, at its own sole
option, any such defective products. This warranty does not apply to equipment that has
been damaged by accident, negligence, or misapplication or has been altered or modified in