7. Device Diagnostics: To utilize the diagnostics tool, access the Device > Diagnostic menu option. The
diagnostics window will appear. This tool can be used to help adjust your device settings to better suit your
deployment scenario. In the diagnostics window there will be three options available for you to test the func-
tion of the unit with the badge tags.
The Test Continuously check-box, when selected, will continuously display the latest Tag IDs, Tag RSSI,
Device RSSI and Com bined RSSI readings of the tags that are in proximity to the Proximity Locator device.
The Test Once button will take a snapshot of the moment and display the tag data for the badge tags that are
in proximity to the locator at that particular point-in-time.
The Add button will prompt a dialog box to enter in a tag ID number. One or more tag IDs can be entered
to test for proximity data readings. Once tag IDs are entered, click either the Test Once button or the Test
Continuously check-box to enable the diagnostic testing. If more than one tag is entered, the tag with the
closest proximity to the locator will appear as highlighted.
Using the Diagnostic mode of the Proximity Locator Utility temporarily disables the reed switch
correlation function of the Proximity Locator device until diagnostic testing is complete.
Figure 7: Test Continuously Diagnostic Reading
Figure 8: Closest Tag Proximity Diagnostic Reading
Mounting
Install the A762 Proximity Locator inside the GOJO LTX Dispenser per GOJO instruc-
tions and procedures.
Install the GOJO LTX Dispenser per GOJO instructions and procedures.